GILCO FIBERS™
Synthetic fiber for concrete ASTM C1116, ASTM C94
Product Description
GILCO FIBERS™ are synthetic micro fibers for concrete made from 100% virgin polypropylene. Designed specifically for use in concrete, they are alkali resistant, non-absorptive and completely non-corrosive. Their use protects concrete from stresses which cause cracking during the first 24 hours after placement while it is most vulnerable. Gilco Fibers comply with ASTM Designation C1116, Standard Specification for Fiber-Reinforced Concrete and Shotcrete, Type III Synthetic Fiber Reinforced Concrete or Shotcrete. They are available in ¾ in (19 mm) length.
Uses
GILCO FIBERS™ may be used in any application where decreased plastic shrinkage cracking and improved durability are desired. Specifically, such applications include but are not limited to, slabs on grade, pavements, overlays, sloped walls, pools, shotcrete, stucco, precast and prestressed products. It is suggested that this product be used in conjunction with properly compacted base materials and jointing in accordance with ACI guidelines and standards.
Gilco Fibers may be used as an alternative to welded wire fabric, depending on the application. Gilco Fibers may not be used as a replacement for structural or post-crack control steel reinforcement. For temperature or shrinkage post-crack control, please consult a GCP Applied Technologies representative regarding our STRUX® synthetic macro fibers.
Product Advantages
Gilco Fibers uniformly distribute multi–dimensionally throughout the concrete. The fibers in the fresh concrete matrix provide reinforcement for the mixture while its tensile strength is weakest The reinforcement reduces the formation of all types of early age cracking. This cracking caused by plastic shrinkage, settlement and other internal stresses would otherwise permanently weaken the resultant concrete. The concrete permeability is decreased, while the surface characteristics, impact and toughness properties are slightly improved. Together these effects work synergistically to produce a long-term, better quality, more durable and serviceable concrete.
Product Advantages
- Reduces plastic shrinkage cracking and improves durability
- Protects concrete from stresses that cause cracking
- Provides cost effective control of plastic shrinkage
- Provides overall higher quality of concrete
Typical Properties
Specific gravity | 0.91 |
Absorption | None |
Length | ¾ in (19 mm) |
Modulus of elasticity | 500 ksi (3.45 GPa) |
Melt point | 320°F (160°C) |
Ignition point | 1094°F (590°C) |
Alkali, acid and salt resistance | High |
Addition Rates
Gilco Fibers may be added to concrete at any point during the batching or mixing process. Gilco Fibers may be added to the aggregate during weighing or charging, or to the central mixer or transit mixer before, during, or after charging. The load must be mixed at mixing speed for 5 minutes, or 70 revolutions, after the addition of the fibers to ensure uniform distribution. The standard range of addition for Gilco Fibers is ¾ to 1½ lb/yd3 (450 to 900 g/m3) of concrete. Typically, 1 lb/yd3 (600 g/m3) of Gilco Fibers provides excellent results when tested according to ASTM C1579. Higher addition rates may be used to produce concrete when special properties are required.
Compatibility with Other Admixtures
Gilco Fibers are compatible with all GCP admixtures. Their action in concrete is purely mechanical and will not affect the hydration process. Each admixture should be added separately.
Packaging & Handling
Gilco Fibers are available in convenient CONCRETE-READY™ bags, which are added, unopened, to the truck drum or central mixer. The specially designed cellulose fiber bag disintegrates and disperses its contents of Gilco Fibers throughout the mix.
Specifications
Fibers shall be ¾ in. (19 mm) monofilament polypropylene fibers as supplied by GCP Applied Technologies, Cambridge, MA 02140. Required dosage rate shall be as specified by the design engineer or architect. Gilco Fibers shall be used in strict accordance with the supplier’s recommendations and within time as specified in ASTM C94. The fibers shall comply with ASTM Designation C1116 Type III 4.1.3 and with applicable building codes. Certification of compliance shall be made available upon request. Standard ACI 302 procedures for placing, finishing and curing shall be followed when using Gilco Fibers.
References
Building Codes–
BOCA National Building Codes, SBCCI Standard Building Code, ICBO Uniform Building Code and all supplements as adopted by the Council of American Building Officials
Fire Classifications–
Underwriters Laboratories (UL) on Series D700 and D800 metal deck assemblies
American Concrete Institute (ACI)–
ACI 544 State of the Art Report of Fiber Reinforced Concrete ACI 302 Guide for Concrete Floor and Slab Construction
ASTM International–
ASTM C1116 Standard Specification for Fiber-Reinforced Concrete and Shotcrete
ASTM C1579 Standard Test Method for Evaluating Plastic Shrinkage Cracking of Restrained Fiber Reinforced Concrete (Using a Steel Form Insert)
ASTM C94 Standard Specification for Ready-Mixed Concrete
gcpat.it | Servizio clienti in Italia:: +39 02 93537291
Confidiamo che le informazioni date con la presente siano utili. Sono basate su dati e conoscenze che riteniamo vere ed accurate e sono messe a disposizione dell’utente perché li consideri, facendo le opportune verifiche. Tali informazioni non rientrano nei nostri obblighi quali fornitori e per esse nessun compenso, esplicito o implicito, viene richiesto e/o viene dato. Anche per questo non assumiamo alcuna responsabilità per l’uso di tali informazioni e per i risultati che possono essere ottenuti. Nessuna informazione, raccomandazione o suggerimento può essere intesa ad un impiego in un processo che violi qualsiasi brevetto, copyright o diritto di terzi.
© Copyright 2017 GCP Applied Technologies Inc. Tutti i diritti riservati.
GCP Applied Technologies Inc., 2325 Lakeview Parkway, Alpharetta, GA 30009, USA
GCP Italiana S.p.A. - Via Trento, 7 - 20017 Passirana di Rho, Milano, Italy
Questo documento è aggiornato solo a partire dalla data dell’ultimo indicato di seguito ed è valido solo per l'uso in Italia. È importante consultare sempre le informazioni attualmente disponibili sull'URL.di seguito per avere le informazioni sul prodotto più recenti al momento dell'uso. Documenti aggiuntivi come i manuali di utilizzo, bollettini tecnici, disegni dettagliati e raccomandazioni dettagliate e altri documenti rilevanti sono disponibili anche su www.gcpat.fr. Le informazioni trovate su altri siti web non dovrebbero essere utilizzati, in quanto potrebbero non essere aggiornati o applicabili alle condizioni del tuo paese e non ci assumiamo alcuna responsabilità quanto al loro contenuto. In caso di conflitti o se hai bisogno di ulteriori informazioni, contatta il servizio clienti di GCP.
Last Updated: 2025-05-15